CITATION — REFERENCE ENTRY

rs-classical · smith-resample

Revision 5184f67b-4e1d-4237-8fe7-8a82e226c481 · 11/27/2026, 1:35:52 AM UTC
Citation
smith-resample
Claim ID
rs-classical
Assertion
Classical sampling-rate conversion interpolates by an integer factor L and decimates by an integer factor M, converting by any rational ratio L/M with a lowpass filter whose cutoff depends on the larger of L and M; this is less convenient for arbitrary times or ratios that change smoothly. When the new rate is lower, the lowpass cutoff must be placed below half the new rate.
Quote
In these techniques, the signal is first interpolated by an integer factor L and then decimated by an integer factor M . ... This provides sampling-rate conversion by any rational factor L/M . ... The conversion requires a digital lowpass filter whose cutoff frequency depends on max{L, M }. ... this formulation is less convenient when it is desired to resample the signal at arbitrary times or change the sampling-rate ... conversion factor smoothly over time. ... When the new sampling rate Fs′ is less than the original rate Fs , the lowpass cutoff must be placed below half the new ... lower sampling rate.
Quote language
en
Locator
section: 3.2 Introduction; 3.3 Theory of Ideal Bandlimited Interpolation
Available in