Claims
-
Fletcher, following Helmholtz, suggested that the peripheral auditory system behaves as if it contains a bank of bandpass filters with overlapping passbands, now called the auditory filters.
"Fletcher [13.13], following Helmholtz [13.14], suggested that the peripheral auditory system behaves as if it contains a bank of bandpass filters, with overlapping passbands. These filters are now called the auditory filters."
-
The equivalent rectangular bandwidth of the normal auditory filter is ERBN = 24.7(0.00437F + 1) Hz at center frequency F (after Glasberg and Moore 1990), about 132 Hz at 1 kHz.
"An equation describing the value of ERBN as a function of center frequency, F (in Hz), is [13.20]: ERBN = 24.7(0.00437F + 1). ... the value of ERBN for a center frequency of 1 kHz is about 132 Hz"
-
The ERBN-number scale is conceptually similar to the Bark scale proposed by Zwicker and coworkers, though it differs somewhat in numerical values.
"This scale is conceptually similar to the Bark scale proposed by Zwicker and coworkers [13.22], although it differs somewhat in numerical values."
-
Non-simultaneous masking takes two forms: backward masking, in which the probe precedes the masker, and forward masking, in which it follows the masker.
"Two basic types of non-simultaneous masking can be distinguished: (1) backward masking, in which the probe precedes the masker; and (2) forward masking, in which the probe follows the masker."
-
Forward masking decays to zero 100 to 200 ms after the masker, regardless of its initial amount; practiced subjects often show little or no backward masking.
"Regardless of the initial amount of forward masking, the masking decays to zero after 100–200 ms. ... practiced subjects often show little or no backward masking"
-
Filtering out the fundamental component of a periodic sound does not alter its pitch, only slightly changing its timbre: the phenomenon of the missing fundamental.
"However, if the sound is filtered so as to remove the fundamental component, the pitch does not alter; the only result is a slight change in timbre. This is called the phenomenon of the missing fundamental"
-
In the power-spectrum model of masking, only the components of a noise that pass through the auditory filter centered on the signal affect its masking.
"Only the components in the noise which pass through the filter have any effect in masking the signal."