CITATION — REFERENCE ENTRY
dr-params · driedger2014-hpr-separation
- Citation
- driedger2014-hpr-separation
- Claim ID
- dr-params
- Assertion
- The median filter lengths matter little unless extreme. The frame size pushes energy towards one component: large frames let percussive sounds leak into the harmonic part, small frames blur horizontal structures so harmonic sounds leak into the percussive part. A larger separation factor makes both parts clearer but sends more of the signal to the residual.
- Quote
Our experiments have shown that the filter lengths actually do not influence the decomposition too much as long as no extreme values are chosen ... For large frame sizes, the short percussive sounds lose influence in the spectral representation and more energy is assigned to the harmonic component. This results in a leakage of some percussive sounds to the harmonic component. Vice versa, for small frame sizes the low frequency resolution often leads to a blurring of horizontal structures, and harmonic sounds tend to leak into the percussive component. ... The larger its value, the clearer becomes the harmonic and percussive nature of the components xh and xp . Meanwhile, also the portion of the signal that is assigned to the residual component xr increases.
- Quote language
- en
- Locator
- section: 3.2 Influence of the Parameters
Available in