CITATION — REFERENCE ENTRY

Psychoacoustics — Springer Handbook of Acoustics

Revision 687756fb-df78-4489-9334-f04f58adf88f · 11/21/2026, 4:44:48 AM UTC
Key
moore2007-psychoacoustics
Authors
Moore, Brian C. J.
Issued
2007
Type
chapter
Container
Springer Handbook of Acoustics
Publisher
Springer
Publisher place
New York
Pages
459-501
Raw CSL JSON
{
  "DOI": "10.1007/978-0-387-30425-0_13",
  "URL": "https://math.ucdavis.edu/~saito/data/auditory/moore_psychoacoustics.pdf",
  "page": "459-501",
  "type": "chapter",
  "title": "Psychoacoustics",
  "author": [
    {
      "given": "Brian C. J.",
      "family": "Moore"
    }
  ],
  "issued": {
    "date-parts": [
      [
        2007
      ]
    ]
  },
  "publisher": "Springer",
  "container-title": "Springer Handbook of Acoustics",
  "publisher-place": "New York"
}

Claims

  1. Fletcher, following Helmholtz, suggested that the peripheral auditory system behaves as if it contains a bank of bandpass filters with overlapping passbands, now called the auditory filters.
    "Fletcher [13.13], following Helmholtz [13.14], suggested that the peripheral auditory system behaves as if it contains a bank of bandpass filters, with overlapping passbands. These filters are now called the auditory filters."
    Locator: section: 13.2.1, p. 462 · Quote language: en
  2. The equivalent rectangular bandwidth of the normal auditory filter is ERBN = 24.7(0.00437F + 1) Hz at center frequency F (after Glasberg and Moore 1990), about 132 Hz at 1 kHz.
    "An equation describing the value of ERBN as a function of center frequency, F (in Hz), is [13.20]: ERBN = 24.7(0.00437F + 1). ... the value of ERBN for a center frequency of 1 kHz is about 132 Hz"
    Locator: section: 13.2.3, Eq. (13.1), p. 464 · Quote language: en
  3. The ERBN-number scale is conceptually similar to the Bark scale proposed by Zwicker and coworkers, though it differs somewhat in numerical values.
    "This scale is conceptually similar to the Bark scale proposed by Zwicker and coworkers [13.22], although it differs somewhat in numerical values."
    Locator: section: 13.2.3, p. 464 · Quote language: en
  4. Non-simultaneous masking takes two forms: backward masking, in which the probe precedes the masker, and forward masking, in which it follows the masker.
    "Two basic types of non-simultaneous masking can be distinguished: (1) backward masking, in which the probe precedes the masker; and (2) forward masking, in which the probe follows the masker."
    Locator: section: 13.2.5, p. 465 · Quote language: en
  5. Forward masking decays to zero 100 to 200 ms after the masker, regardless of its initial amount; practiced subjects often show little or no backward masking.
    "Regardless of the initial amount of forward masking, the masking decays to zero after 100–200 ms. ... practiced subjects often show little or no backward masking"
    Locator: section: 13.2.5, p. 465 · Quote language: en
  6. Filtering out the fundamental component of a periodic sound does not alter its pitch, only slightly changing its timbre: the phenomenon of the missing fundamental.
    "However, if the sound is filtered so as to remove the fundamental component, the pitch does not alter; the only result is a slight change in timbre. This is called the phenomenon of the missing fundamental"
    Locator: section: 13.5.3, p. 480 · Quote language: en
  7. In the power-spectrum model of masking, only the components of a noise that pass through the auditory filter centered on the signal affect its masking.
    "Only the components in the noise which pass through the filter have any effect in masking the signal."
    Locator: section: 13.2.1, p. 462 · Quote language: en
Available in