- Assertion
- Reverberation time, the most common measure of damping in rooms for historical reasons going back to Sabine, the founder of room acoustics, is the time for the sound pressure level to drop 60 dB after a steady source is switched off.
- Quote
Largely for historical reasons which date back to the works of W. C. Sabine (the founder of room acoustics), the quantity which is most frequently used for expressing damping in rooms is not the damping constant ζ, but the reverberation time29 T60 . It is defined as the time interval during which sound pressure level in a room drops 60 dB after its source of stationary sound is switched off.
- Quote language
- en
- Locator
- page: 39