CITATION — REFERENCE ENTRY
Simultaneous Measurement of Impulse Response and Distortion with a Swept-Sine Technique — Audio Engineering Society 108th Convention
- Key
- farina2000-swept-sine
- Authors
- Farina, Angelo
- Issued
- 2000-2
- Type
- paper-conference
- Container
- Audio Engineering Society 108th Convention
Raw CSL JSON
{
"URL": "https://www.aes.org/e-lib/browse.cfm?elib=10211",
"note": "Quotes checked against the author's copy at http://www.angelofarina.it/Public/Papers/134-AES00.PDF.",
"type": "paper-conference",
"title": "Simultaneous Measurement of Impulse Response and Distortion with a Swept-Sine Technique",
"author": [
{
"given": "Angelo",
"family": "Farina"
}
],
"issued": {
"date-parts": [
[
2000,
2
]
]
},
"number": "Preprint 5093",
"event-place": "Paris, France",
"container-title": "Audio Engineering Society 108th Convention"
}
Claims
-
Farina's 2000 method measures the transfer function of weakly nonlinear, approximately time-invariant systems with an exponentially swept sine, using low-cost equipment, for loudspeakers and other audio components as well as rooms. The established methods, maximum length sequences (MLS) and time-delay spectrometry, assume perfect linearity and time-invariance; MLS in particular tolerates nonlinearity and time variance poorly and needs the excitation tightly synchronized with the recorder.
"A novel measurement technique of the transfer function of weakly not-linear, approximately time-invariant systems is presented. The method is implemented with low-cost instrumentation; it is based on an exponentially-swept sine signal. It is applicable to loudspeakers and other audio components, but also to room acoustics measurements. ... for the impulse response measurement the most employed technique are MLS (Maximum Length Sequence) and TDS (Time-Delay Spectrometry). Both these methods are based on the assumption of perfect linearity and time-invariance of the system, and give problems when these assumptions are not met. In particular MLS is quite delicate, it does not tolerate very well nonlinearity or time-variance, and requires that the excitation signal is tightly synchronised with the digital sampler employed for recording the system's response."
-
For a linear time-invariant system the output is the convolution of the input with the system's impulse response. A room excited through a loudspeaker is a typical case of a system whose nonlinearity sits at the start, in the transducer, followed by linear propagation with reflections, echoes and reverberation.
"If the system is linear and time-invariant, the function F assumes the form of the convolution between the input signal and the system’s impulse response h(t) ... This scenario is typical, for example, of a reverberant space excited through a loudspeaker: the distortion occurs in the electro-mechanical transducer, but as the sound is radiated into air, it passes through a subsequent linear propagation process, including multiple reflections, echoes and reverberation."
-
Deconvolving the response to an exponential sweep yields the system's linear impulse response and, separated along the time axis, an impulse response for each order of harmonic distortion, so one fast measurement characterizes the system completely; it proved robust to minor time variance and to mismatched clocks between playback and recording.
"It was discovered that employing a sine signal with exponentially varied frequency, it is possible to deconvolve simultaneously the linear impulse response of the system, and separate impulse responses for each harmonic distortion order. In practice, after the deconvolution of the sampled response, a sequence of impulse responses appears, clearly separated along the time axis. ... This means that the system is characterised completely with a single, fast and simple measurement ... Furthermore, the system revealed to be very robust to minor time-variance of the system under test, and to mismatch between the sampling clock of the signal generation and recording."
Available in