CITATION — REFERENCE ENTRY

fa-abstract · farina2000-swept-sine

Revision 0a94f307-3518-4c77-99b4-66ba9a6c2da8 · 11/27/2026, 1:35:50 AM UTC
Claim ID
fa-abstract
Assertion
Farina's 2000 method measures the transfer function of weakly nonlinear, approximately time-invariant systems with an exponentially swept sine, using low-cost equipment, for loudspeakers and other audio components as well as rooms. The established methods, maximum length sequences (MLS) and time-delay spectrometry, assume perfect linearity and time-invariance; MLS in particular tolerates nonlinearity and time variance poorly and needs the excitation tightly synchronized with the recorder.
Quote
A novel measurement technique of the transfer function of weakly not-linear, approximately time-invariant systems is presented. The method is implemented with low-cost instrumentation; it is based on an exponentially-swept sine signal. It is applicable to loudspeakers and other audio components, but also to room acoustics measurements. ... for the impulse response measurement the most employed technique are MLS (Maximum Length Sequence) and TDS (Time-Delay Spectrometry). Both these methods are based on the assumption of perfect linearity and time-invariance of the system, and give problems when these assumptions are not met. In particular MLS is quite delicate, it does not tolerate very well nonlinearity or time-variance, and requires that the excitation signal is tightly synchronised with the digital sampler employed for recording the system's response.
Quote language
en
Locator
section: Abstract; 1 Introduction
Available in