Assertion
With the separation factor β, a time–frequency bin counts as harmonic only if its harmonically enhanced value exceeds the percussively enhanced one by at least a factor of β, and vice versa; everything else goes to the residual, and the three components always add up to the original signal.
Quote
Intuitively, for a sound to be included in the harmonic component it is required to stand out from the percussive portion of the signal by at least a factor of β, and vice versa for the percussive component. ... It contains the portion of the input signal x that is neither part of the harmonic component xh nor the percussive components xp . ... The three components always add up to the original signal again.
Quote language
en
Locator
section: 2; 3.1